特點:
1、電動吸引器由負壓泵、負壓調節(jié)器、負壓指示器、收集容器組件、腳踏開關、機箱組成;
2、電動吸引器可供醫(yī)療單位作手術吸引膿血和各種粘質分泌物用,本機采用二級負壓裝置(負壓泵工作進行貯氣為一級負壓,內置貯氣桶容量為5000ml,手術吸引壓力為二級負壓,特別適用于二級靜音流產吸引);
3、立式結構、設計新穎、外形美觀;
4、采用雙頭活塞式真空泵作為負壓吸引源,噪音小;
5、設有防溢流安全裝置,保養(yǎng)維護工作簡單,無需加油;
6、手動和腳踏開關并聯任意使用,操作方便,手術安全,手術操作時無噪音,消除了病人的恐懼心理;
7、電動吸引器按防電擊類型及程度分類為Ⅰ類設備B型應用部分,運行模式為間歇加載連續(xù)運行(間歇吸引),IPX0、非AP型或APG型普通設備;
8、產品符合GB9706.1、YY0505、YY0636.1相關要求。
技術指標
1、負壓極限值∶≥0.09MPa(680mmHg);
2、負壓調節(jié)范圍∶ 0.02~0.09MPa(150~680mmHg);
3、抽氣速率∶ 泵口(出氣口)≥30L/min,終端≥20L/min;
4、電源∶ AC220V±22V,50Hz±1Hz;
5、功率∶280VA;
6、噪聲∶≤60dB;
7、收集容器容量∶1000ml×2;
8、工作環(huán)境∶溫度+5℃~ +35℃,相對濕度∶ 25℃不超過80%,大氣壓力∶ 86KPa~106KPa。
Features:
1. The electric suction device is composed of a negative pressure pump, a negative pressure regulator, a negative pressure indicator, a collection container assembly, a foot switch, and a chassis;
2. The electric suction device can be used by medical units for surgical suction of pus and blood and various mucous secretions. This machine adopts a secondary negative pressure device (the negative pressure pump works to store air as a primary negative pressure, and the built-in air storage bucket capacity 5000ml, the surgical suction pressure is secondary negative pressure, especially suitable for secondary silent abortion suction);
3. Vertical structure, novel design, beautiful appearance;
4. Double-head piston vacuum pump is used as the suction source of negative pressure with low noise;
5. Equipped with anti-overflow safety device, maintenance work is simple, no need to refuel;
6. The manual and foot switch can be used in parallel, and the operation is convenient, the operation is safe, and there is no noise during the operation, which eliminates the fear of the patient;
7. According to the type and degree of electric shock prevention, the electric suction device is classified into the application part of type I equipment, and the operation mode is intermittent loading and continuous operation (intermittent suction), IPX0, non-AP type or APG type ordinary equipment;
8. The product meets the relevant requirements of GB9706.1, YY0505, and YY0636.1.
Technical index
1. Negative pressure limit value: ≥0.09MPa (680mmHg);
2. Negative pressure adjustment range: 0.02~0.09MPa (150~680mmHg);
3. Pumping rate: pump port (air outlet) ≥30L/min, terminal ≥20L/min;
4. Power supply: AC220V±22V, 50Hz±1Hz;
5. Power: 280VA;
6. Noise: ≤60dB;
7. Collection container capacity: 1000ml×2;
8. Working environment: temperature +5℃~+35℃, relative humidity: 25℃ not more than 80%, atmospheric pressure: 86KPa~106KPa.